Commissioning and Trial Run
126
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
U0‑88 28760 Alarm code Model
dependent
Modification
prohibited
U0‑89 28761 Alarm subcode Model
dependent
Modification
prohibited
U0‑90 28762 Fan speed percentage
setting
Model
dependent
Modification
prohibited
U0‑91 28763 PTC1 mode Model
dependent
Modification
prohibited
U0‑92 28764 PTC2 mode Model
dependent
Modification
prohibited
U0‑93 28765 PTC3 mode Model
dependent
Modification
prohibited
U0‑95 28767 STO initialization flag Model
dependent
Modification
prohibited
U0‑96 28768 STO status word
monitoring
Model
dependent
Modification
prohibited
U0‑97 28769 STO model Model
dependent
Modification
prohibited
U0‑98 28770 STO AD sampling
value
Model
dependent
Modification
prohibited
U0‑99 28771 STO internal
execution flag
Model
dependent
Modification
prohibited
U3‑16 29456 Frequency set through
communication
065535 0 Modification
prohibited
U3‑17 29457 Communication
control command
0: Stop according to F6‑10
1: Forward running
2: Reverse running
3: Forward jog
4: Reverse jog
5: Coast to stop
6: Decelerate to stop
7: Fault reset
0 Modification
prohibited
U3‑18 29458 Communication
control DO/RO
Bit0: DO1/RO1
Bit1: DO2/RO2
Bit2: DO3/RO3
Bit3: DO4/RO4
Bit4: DO5/RO5
0 Modification
prohibited
U4‑00 29696 Fault code 065535 0 Modification
prohibited
U4‑01 29697 Control word 065535 0 Modification
prohibited
U4‑02 29698 Status word 065535 0 Modification
prohibited
U4‑03 29699 Target speed 065535 0 rpm Modification
prohibited

Other manuals for Inovance MD800 Series