Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
A0‑14 40974 Expansion card 2 ‑
Frame loss times
0–65535 0 ‑ Modification
prohibited
A0‑15 40975 Expansion card 3 ‑
Frame loss times
0–65535 0 ‑ Modification
prohibited
A1‑00 41216 Filter time of power
supply unit terminals
(DI1 to DI4)
0.000s to 5.000s 0.010 s Modifiable
in any states
A1‑01 41217 Filter time of power
supply unit terminals
(DI5 to DI8)
0.000s to 5.000s 0.010 s Modifiable
in any states
A1‑05 41221 AI1 filter time 0.00s to 10.00s 0.10 s Modifiable
in any states
A1‑06 41222 AI2 filter time 0.00s to 10.00s 0.10 s Modifiable
in any states
A1‑10 41226 AI1 input selection 0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 ‑ Modifiable
only at stop
A1‑11 41227 AI2 input selection 0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 ‑ Modifiable
only at stop
A2‑00 41472 Filter time of
expansion card 1
terminals (DI1 to DI4)
0.000s to 5.000s 0.010 s Modifiable
in any states
A2‑01 41473 Filter time of
expansion card 1
terminals (DI5 to DI8)
0.000s to 5.000s 0.010 s Modifiable
in any states
A2‑05 41477 AI1 filter time 0.00s to 10.00s 0.10 s Modifiable
in any states
A2‑06 41478 AI2 filter time 0.00s to 10.00s 0.10 s Modifiable
in any states
A2‑10 41482 AI1 input selection 0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
0 ‑ Modifiable
only at stop