Commissioning and Trial Run
74
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F2‑09 61961 Torque upper limit
source in speed
control (motoring)
0: Digital setting (F2‑10)
1: AI1
2: AI2
3: AI3
4: Reserved
5: Communication setting
6: Min. (AI1, AI2)
7: Max. (AI1, AI2)
0 Modifiable
in any states
F2‑10 61962 Digital setting of
torque upper limit in
speed control
(electric)
0.0% to 200.0% 150.0 % Modifiable
in any states
F2‑11 61963 Torque upper limit
source in speed
control (generating)
0: Digital setting (F2‑10)
1: AI1
2: AI2
3: AI3
4: Reserved
5: Communication setting
6: Min. (AI1, AI2)
7: Max. (AI1, AI2)
8: Digital setting (F2‑12)
0 Modifiable
in any states
F2‑12 61964 Digital setting of
torque upper limit in
speed control
(generating)
0.0% to +200.0% 150.0 % Modifiable
in any states
F2‑13 61965 Current loop
proportional gain Kp
at low speed
0.110.0 1.0 Modifiable
in any states
F2‑14 61966 Current loop integral
gain Ki at low speed
0.110.0 1.0 Modifiable
in any states
F2‑15 61967 Current loop
proportional gain Kp
at high speed
0.110.0 1.0 Modifiable
in any states
F2‑16 61968 Current loop integral
gain Ki at high speed
0.110.0 1.0 Modifiable
in any states
F2‑17 61969 Speed loop
proportional gain Kp
at zero speed lock
1100 30 Modifiable
in any states
F2‑18 61970 Speed loop integral
time Ti at zero speed
lock
0.001s to 10.000s 0.500 s Modifiable
in any states
F2‑20 61972 Speed loop
switchover frequency
at zero speed lock
0.00655.35 Hz 05 Hz Modifiable
in any states
F2‑21 61973 Maximum output
voltage coefficient
100110 100 Modifiable
in any states