Commissioning and Trial Run
‑78‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F3‑32 62240 Automatic frequency
rise KI
0–100 50 ‑ Modifiable
in any states
F3‑33 62241 Online torque
compensation gain
80–150 100 ‑ Modifiable
only at stop
F4‑00 62464 DI1 hardware source 0: No selection
1: Power supply unit ‑ DI1
2: Power supply unit ‑ DI2
3: Power supply unit ‑ DI3
4: Power supply unit ‑ DI4
5: Power supply unit ‑ DIO1
6: Power supply unit ‑ DIO2
7: Power supply unit ‑ DIO3
8: Power supply unit ‑ DIO4
101: Expansion card 1 ‑ DI1
102: Expansion card 1 ‑ DI2
103: Expansion card 1 ‑ DI3
104: Expansion card 1 ‑ DI4
105: Expansion card 1 ‑ DI5
106: Expansion card 1 ‑ DI6
107: Expansion card 1 ‑ DI7
108: Expansion card 1 ‑ DI8
201: Expansion card 2 ‑ DI1
202: Expansion card 2 ‑ DI2
203: Expansion card 2 ‑ DI3
204: Expansion card 2 ‑ DI4
205: Expansion card 2 ‑ DI5
206: Expansion card 2 ‑ DI6
207: Expansion card 2 ‑ DI7
208: Expansion card 2 ‑ DI8
0 ‑ Modifiable
only at stop