Commissioning and Trial Run
‑80‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
(continued) 62465 DI1 function selection 24: Switchover between
main frequency reference
X and preset frequency
25: Switchover between
auxiliary frequency
reference Y and preset
frequency
26: Frequency
modification enable
27: Counter input
28: Counter reset
29: Length count input
30: Length reset
31: PID pause
32: PID integral pause
33: PID parameter
switchover
34: PID action direction
reverse
35: Torque control
prohibition
36: Speed control/Torque
control switchover
38: Speed tracking enable
39: Immediate DC braking
40: Deceleration DC
braking
41: External stop terminal
1
42: External stop terminal
2
43: Running pause
44: Coast to stop
45: Emergency stop
46: Motor selection
terminal
47: Clear the current
running time
48: Two‑wire/Three‑wire
control switchover
49: PLC state reset
50: Wobble pause
54–63: Reserved
1 ‑ Modifiable
only at stop
F4‑02 62466 DI2 hardware source Same as F4‑00 0 ‑ Modifiable
only at stop
F4‑03 62467 DI2 function selection Same as F4‑01 4 ‑ Modifiable
only at stop