Commissioning and Trial Run
‑83‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F4‑27 62491 AI2 hardware source 0: No selection
1: AI1 of power supply unit
2: AI2 of power supply unit
101: AI1 of expansion card
1
102: AI2 of expansion card
1
201: AI1 of expansion card
2
202: AI2 of expansion card
2
0 ‑ Modifiable
only at stop
F4‑29 62493 AI3 hardware source 0: No selection
1: AI1 of power supply unit
2: AI2 of power supply unit
101: AI1 of expansion card
1
102: AI2 of expansion card
1
201: AI1 of expansion card
2
202: AI2 of expansion card
2
0 ‑ Modifiable
only at stop
F4‑31 62495 AI curve 1 minimum
input
‑10.00 V to +10.00 V 0.00 V Modifiable
in any states
F4‑32 62496 Corresponding
percentage of AI curve
1 minimum input
‑100.0% to +100.0% 0.0 % Modifiable
in any states
F4‑33 62497 AI curve 1 maximum
input
‑10.00 V to +10.00 V 10.00 V Modifiable
in any states
F4‑34 62498 Corresponding
percentage of AI curve
1 maximum input
‑100.0% to +100.0% 100.0 % Modifiable
in any states
F4‑35 62499 AI curve 2 minimum
input
‑10.00 V to +10.00 V 0.00 V Modifiable
in any states
F4‑36 62500 Corresponding
percentage of AI curve
2 minimum input
‑100.0% to +100.0% 0.0 % Modifiable
in any states
F4‑37 62501 AI curve 2 maximum
input
‑10.00 V to +10.00 V 10.00 V Modifiable
in any states
F4‑38 62502 Corresponding
percentage of AI curve
2 maximum input
‑100.0% to +100.0% 100.0 % Modifiable
in any states
F4‑39 62503 AI curve 3 minimum
input
‑10.00 V to +10.00 V 0.00 V Modifiable
in any states