Commissioning and Trial Run
88
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F5‑11 62731 DO2/RO2 output delay 0.0s to 3600.0s 0.0 s Modifiable
in any states
F5‑12 62732 DO3/RO3 output delay 0.0s to 3600.0s 0.0 s Modifiable
in any states
F5‑13 62733 DO4/RO4 output delay 0.0s to 3600.0s 0.0 s Modifiable
in any states
F5‑14 62734 DO5/RO5 output delay 0.0s to 3600.0s 0.0 s Modifiable
in any states
F5‑15 62735 DO/RO active mode
selection
Ones:
0: Positive logic active
1: Negative logic active
Tens:
0: Positive logic active
1: Negative logic active
Hundreds:
0: Positive logic active
1: Negative logic active
Thousands:
0: Positive logic active
1: Negative logic active
Ten thousands:
0: Positive logic active
1: Negative logic active
0 Modifiable
in any states
F6‑00 62976 Startup mode 0: Direct start
1: Flying start
(asynchronous motor)
2: Pre‑excited start
(asynchronous motor)
0 Modifiable
in any states
F6‑01 62977 Flying start mode 0: From stop frequency
1: From 50 Hz
2: From the maximum
frequency
3: Fast flying start
0 Modifiable
only at stop
F6‑02 62978 Flying start speed 1100 20 Modifiable
in any states
F6‑03 62979 Startup frequency 0.0010.00 kHz 0.00 Hz Modifiable
in any states
F6‑04 62980 Startup frequency
active time
0.0s to 100.0s 0.0 s Modifiable
only at stop
F6‑05 62981 Startup DC braking
current/pre‑excitation
current
0% to 100% 0 % Modifiable
only at stop
F6‑06 62982 Startup DC braking
active time/pre‑
excitation active time
0.0s to 100.0s 0.0 s Modifiable
only at stop