Commissioning and Trial Run
90
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F6‑30 63006 Synchronous motor
flying start trial
current
5.0% to 50.0% 20.0 % Modifiable
only at stop
F6‑31 63007 Minimum tracking
frequency for
synchronous motor
flying start
0.0100.0 Hz 0.0 Hz Modifiable
only at stop
F6‑32 63008 Angle compensation
for synchronous
motor flying start
0360 0 Modifiable
only at stop
F6‑33 63009 Proportional
coefficient for
synchronous motor
flying start
0.110.0 2.0 Modifiable
only at stop
F6‑34 63010 Integral coefficient for
synchronous motor
flying start
0.110.0 6.0 Modifiable
only at stop
F6‑35 63011 Reverse running
disabled for flying
start
02 0 Modifiable
in any states
F7‑00 63232 Drive unit light test 02 0 Modifiable
in any states
F7‑01 63233 MF.K key function
selection
0: MF.K key disabled
1: Switchover between
operating panel control
and remote command
control (terminal or
communication)
2: Switchover between
forward and reverse
running
3: Forward jog
4: Reverse jog
0 Modifiable
only at stop
F7‑02 63234 STOP key function 0: Valid only under
operating panel control
1: Valid in all operating
modes
0 Modifiable
in any states