Installation Preparations
‑13‑
3 Installation Preparations
3.1 Installation Environment
Table 3–1 Environment requirement
Item
Requirement
Installation
location
Indoors
Grid
overvoltage
Overvoltage Class III (OVC III).
Altitude
The maximum altitude is 2000 m.
For altitudes not higher than 1000 m, derating is not required.
Derating is required for altitudes above 1000 m (derate 1% for
every additional 100 m).
For altitudes above 2000 m, contact Inovance.
Temperature
Mounting/Operating temperature: 0℃ to +55℃ For temperatures
between 0℃ to 45℃, derating is not required. For temperatures
above 45℃, derate 2% for every additional 1℃.
Storage/Transportation temperature: ‑40℃ to +70℃.
To improve the reliability of the machine, use the servo drive in
environments without dramatic temperature change.
When installing the servo drive into an enclosed environment such
as a control cabinet, use a cooling fan or air conditioner to keep the
temperature of the inlet air below 45℃. Failure to comply will
result in overheat or fire.
Install the servo drive on the surface of an incombustible object
and leave sufficient surrounding space for heat dissipation.
Take measures to prevent the servo drive from being frozen.
Ambient
humidity
Below 90% RH (no condensation)
Storage
humidity
Below 90% RH (no condensation)
Vibration
resistance
Operation:
5 Hz8.4 Hz: 3.5 mm displacement
8.4 Hz200 Hz: 1g
Product package:
5 Hz100 Hz:0.01g
2
/Hz
200 Hz: 0.001g
2
/Hz
Grms = 1.14 g
Impact
resistance
Below 19.6m/s