3.1 Installation Environment
Table 3–1 Environment requirement
Item
Requirement
Installation
location
Indoors
Grid
overvoltage
Overvoltage Class III (OVC III).
Altitude
The maximum altitude is 2000 m.
● For altitudes not higher than 1000 m, derating is not required.
● Derating is required for altitudes above 1000 m (derate 1% for
every additional 100 m).
● For altitudes above 2000 m, contact Inovance.
Temperature
● Mounting/Operating temperature: 0℃ to +55℃ For temperatures
between 0℃ to 45℃, derating is not required. For temperatures
above 45℃, derate 2% for every additional 1℃.
● Storage/Transportation temperature: ‑40℃ to +70℃.
● To improve the reliability of the machine, use the servo drive in
environments without dramatic temperature change.
● When installing the servo drive into an enclosed environment such
as a control cabinet, use a cooling fan or air conditioner to keep the
temperature of the inlet air below 45℃. Failure to comply will
result in overheat or fire.
● Install the servo drive on the surface of an incombustible object
and leave sufficient surrounding space for heat dissipation.
● Take measures to prevent the servo drive from being frozen.
Ambient
humidity
Below 90% RH (no condensation)
Storage
humidity
Below 90% RH (no condensation)
Vibration
resistance
Operation:
● 5 Hz–8.4 Hz: 3.5 mm displacement
● 8.4 Hz–200 Hz: 1g
Product package:
● 5 Hz–100 Hz:0.01g
2
/Hz
● 200 Hz: 0.001g
2
/Hz
● Grms = 1.14 g
Impact
resistance
Below 19.6m/s
2