3400 Series Dual Column Table Model
Operator’s Guide
M10-17318-EN Revision C

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Instron 34TM-10 and is the answer not in the manual?

Summary

Chapter 1: Introduction

System Safety and Information Labeling

Explains the meaning of safety and information labels on the equipment.

Chapter 2: Risk Reduction and Safe Use

Residual Risks

Discusses inherent hazards in materials testing systems and external influences.

Operator Protection Overview

Explains the Bluehill® software feature for limiting crosshead speed and grip pressure.

Chapter 4: Function of Controls

Emergency Stop Button

Explains the function and use of the large, round, red emergency stop button.

Operator Protection

Explains software features to limit crosshead speed and grip pressure during setup.

Chapter 5: Assemble the Load String

Preload the Load String

Procedure to eliminate backlash and deflections in the load string.

Chapter 6: Testing Specimens

Calibrate a Transducer

Procedures for automatic and manual calibration of force or strain transducers.

Crosshead Limit Stops

Setting physical travel limits to prevent unexpected crosshead movement.

Chapter 7: Maintenance

Troubleshooting for Load Cells

Guidance on identifying and resolving issues related to load cells.

Summary

Chapter 1: Introduction

System Safety and Information Labeling

Explains the meaning of safety and information labels on the equipment.

Chapter 2: Risk Reduction and Safe Use

Residual Risks

Discusses inherent hazards in materials testing systems and external influences.

Operator Protection Overview

Explains the Bluehill® software feature for limiting crosshead speed and grip pressure.

Chapter 4: Function of Controls

Emergency Stop Button

Explains the function and use of the large, round, red emergency stop button.

Operator Protection

Explains software features to limit crosshead speed and grip pressure during setup.

Chapter 5: Assemble the Load String

Preload the Load String

Procedure to eliminate backlash and deflections in the load string.

Chapter 6: Testing Specimens

Calibrate a Transducer

Procedures for automatic and manual calibration of force or strain transducers.

Crosshead Limit Stops

Setting physical travel limits to prevent unexpected crosshead movement.

Chapter 7: Maintenance

Troubleshooting for Load Cells

Guidance on identifying and resolving issues related to load cells.

Instron 34TM-10 Specifications

General IconGeneral
Maximum Force Capacity10 kN
Number of Columns2
Power Requirements100-240 VAC, 50/60 Hz
Accuracy±0.5% of reading
Crosshead Speed0.001 to 1000 mm/min