EasyManua.ls Logo

Instron 3400 Series User Manual

Instron 3400 Series
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
3400 Series Single Column Table Model
Operator’s Guide
M10-17313-EN Revision B

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Instron 3400 Series and is the answer not in the manual?

Instron 3400 Series Specifications

General IconGeneral
BrandInstron
Model3400 Series
CategoryTest Equipment
LanguageEnglish

Summary

General Safety Precautions

Warnings

Details specific hazards and necessary precautions for safe operation of the testing system.

Chapter 1 Introduction

System Description and Terminology

Describes the components and terminology of the testing system, including labeled diagrams.

System Safety and Information Labeling

Explains the meaning of safety and information labels used on the testing system.

Conformity with EU directives

Declares the system's conformity with relevant EU regulations and directives.

Product Support

Information on how to obtain documentation, online help, and contact support services.

Product Documentation

Details the range of documentation available for Instron products.

Chapter 2 Risk reduction and safe use

Residual risks

Discusses inherent risks in using testing equipment and recommends risk assessment.

Rapid crosshead motion

Addresses crush hazard from rapid crosshead movement and provides safety recommendations.

Pinching fingers between grip jaw faces

Highlights pinch hazard and offers recommendations for safe grip operation.

Impact of debris from breaking specimens

Covers hazard from flying debris and necessary safety precautions.

Operator Protection Overview

Explains the Bluehill® Operator Protection feature for limiting speeds and pressures.

Chapter 3 Installation

Level the load frame

Procedure for leveling the testing system's load frame for stability and accuracy.

Power supply compatibility

Verifies voltage and plug compatibility with the facility's power supply.

System components

Details the various components of the testing system and their connections.

Single column load frame

Describes the frame connections for the single column load frame.

Chapter 4 Function of controls

Power input connector

Explains the functions of the power input connector, including ON/OFF switch and voltage setting.

Emergency Stop button

Details the operation and safety implications of the emergency stop button.

Frame Control Panel

Describes the controls and indicators on the testing system's frame control panel.

Bluehill® software

Outlines the software controls for setting parameters and collecting data.

Operator Protection

Explains the software feature to limit crosshead speed and grip pressure during setup.

Pneumatic Grips

Details the recommended pneumatic grips and their integration with Operator Protection.

Chapter 5 Assemble the load string

Select a load cell

Guidelines for choosing the appropriate load cell based on expected test loads.

Install the load cell

Step-by-step instructions for installing load cells, including specific models.

Select Grips and Fixtures

Guidance on selecting grips and fixtures based on specimen properties.

Install grips

Procedure for installing grips onto the load cell and base adapter.

Preload the load string

Procedure to eliminate backlash and deflections in the load string.

Chapter 6 Testing specimens

Testing a sample

Guidelines for testing a group of specimens, with scenarios for interlock and no interlock.

Testing with no interlock

Procedure for testing when the system has no interlock accessory.

Testing with an interlock accessory

Procedure for testing when the system includes an interlock accessory.

Create a new sample

Steps to create a new sample file in the software.

Calibrate a transducer

Procedures for automatic and manual calibration of force or strain transducers.

Set the zero displacement point

Sets the transducer value to zero, defining the starting point for displacement measurement.

Crosshead limit stops

Explains setting hardware limits for crosshead travel to prevent over-travel.

Set the limits for a transducer

Procedure to enable and set maximum/minimum limits for transducers.

Balance a transducer configuration

Balances transducer configurations by removing offsets and resetting the value to zero.

Stop a test

Methods to stop a test using hardware controls or software settings.

Shut down the system

Steps for safely shutting down the testing system and its components.

Troubleshooting

Addresses common issues like limit trips and suggests solutions.

Chapter 7 Maintenance

Preventive Maintenance

Guidelines for periodic inspection, cleaning, and lubrication of the test system.

General Maintenance Procedures

Procedures that can be performed by the user for system maintenance.

Troubleshooting for Load Cells

Information on diagnosing and resolving issues with load cells.

Ancillary parts

Lists and describes ancillary parts included with the system.