3400 Series Dual Column Table Model
Operator’s Guide
M10-17318-EN Revision C

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Instron 34TM-5 and is the answer not in the manual?

Summary

General Safety Precautions

System Hazards and Warnings

Details various hazards like crush, debris, electrical, temperature, and explosion risks.

Chapter 2 Risk reduction and safe use

Residual risks

Discusses inherent risks in using the testing equipment and influencing factors.

Rapid crosshead motion

Addresses crush hazard to fingers or hands from rapid crosshead movement.

Chapter 3 Installation

Chapter 4 Function of controls

Chapter 5 Assemble the load string

Install the load cell

Step-by-step instructions for installing various load cell models.

Preload the load string

Procedure to eliminate backlash and deflections in the load string for accurate results.

Chapter 6 Testing specimens

Calibrate a transducer

Instructions for calibrating force or strain transducers automatically or manually.

Crosshead limit stops

Importance and function of setting crosshead travel limits for safety.

Emergency Stop Button

Detailed explanation of the Emergency Stop button's function and reset procedure.

Troubleshooting

Guidance for resolving common issues like transducer limit trips and overtravel.

Chapter 7 Maintenance

Troubleshooting for Load Cells

Information on diagnosing and resolving issues related to load cells.

Summary

General Safety Precautions

System Hazards and Warnings

Details various hazards like crush, debris, electrical, temperature, and explosion risks.

Chapter 2 Risk reduction and safe use

Residual risks

Discusses inherent risks in using the testing equipment and influencing factors.

Rapid crosshead motion

Addresses crush hazard to fingers or hands from rapid crosshead movement.

Chapter 3 Installation

Chapter 4 Function of controls

Chapter 5 Assemble the load string

Install the load cell

Step-by-step instructions for installing various load cell models.

Preload the load string

Procedure to eliminate backlash and deflections in the load string for accurate results.

Chapter 6 Testing specimens

Calibrate a transducer

Instructions for calibrating force or strain transducers automatically or manually.

Crosshead limit stops

Importance and function of setting crosshead travel limits for safety.

Emergency Stop Button

Detailed explanation of the Emergency Stop button's function and reset procedure.

Troubleshooting

Guidance for resolving common issues like transducer limit trips and overtravel.

Chapter 7 Maintenance

Troubleshooting for Load Cells

Information on diagnosing and resolving issues related to load cells.

Instron 34TM-5 Specifications

General IconGeneral
Maximum Force Capacity5 kN
Frame TypeSingle column
Number of Columns1
ControlBluehill Universal Software
Force Accuracy±0.5% of reading down to 1/1000 of load cell capacity
Power Requirements100-240 V, 50/60 Hz
Weight95 kg