Intel® Server S2600WT Product Family Configuration Guide and Spares/Accessories List
44
For R2224WTxxx System configurations with no SAS Expander, reference Tables 7, 8, and 9 for cable guidance for all three drive bay modules.
Table 9. 2U 8 x 2.5” (Drive Bay #3) SAS / SATA Data Cable Guide (with no SAS Expander)
System
Configuration
Drive
Support
Cables for On-board
Multi-port SATA Ports
to Drive Bay #3
Cables for Mezzanine
12 Gb SAS ROC Module
to Drive Bay #3
Cables for Mezzanine
6 Gb SAS ROC module
to Drive Bay #3
Cables for 12 Gb SAS
RAID PCIe* add-in
card to Drive Bay #3
Cables for 6 Gb SAS
RAID PCIe* add-in
card to Drive Bay #3
Drive Bay #3
(no SAS
Expander)
R2224
8 x 2.5”
Cable Connections:
SATA Cntlr -> BP 0-3
800mm HD -- HD
sSATA Cntrl -> BP 4-7
730mm HD -- HD
From data above, select
appropriate cable kits
from list below:
AXXCBL730HDHD
(2) 730mm cables
Included in all 2.5” L6)
AXXCBL800HDHD
Cable Connections:
SAS Mezz -> BP 0-3
730mm HD -- HD
SAS Mezz -> BP 4-7
730mm HD -- HD
From data above, select
appropriate cable kits from
list below:
AXXCBL730HDHD
(2) 730mm cables Included
in all 2.5” L6)
Cable Connections:
SAS Mezz -> BP 0-3
730mm HD -- MS
SAS Mezz -> BP 4-7
730mm HD -- MS
From data above, select
appropriate cable kits
from list below:
AXXCBL730HDMS
From Riser #1:
SAS PCIe -> BP 0-3 **
730 or 875mm HD -- HD
SAS PCIe -> BP 4-7 **
800 or 950mm HD -- HD
From Riser #2:
SAS PCIe -> BP 0-3 **
730 or 875mm HD -- HD
SAS PCIe -> BP 4-7 **
650 or 800mm HD -- HD
From data above, select
appropriate cable kits
from list below:
AXXCBL650HDHD
AXXCBL730HDHD
(2) 730mm Included in all
2.5” L6
AXXCBL800HDHD
AXXCBL875HDHD
(4) 875mm Included in
R2224 L6
AXXCBL950HDHD
From Riser #1:
SAS PCIe -> BP 0-3 **
730 or 875mm HD -- MS
SAS PCIe -> BP 4-7 **
800 or 950mm HD -- MS
From Riser #2:
SAS PCIe -> BP 0-3 **
800 or 875mm HD -- MS
SAS PCIe -> BP 4-7 **
650 or 800mm HD -- MS
From data above, select
appropriate cable kits
from list below:
AXXCBL650HDMS
AXXCBL730HDMS
AXXCBL800HDMS
AXXCBL875HDMS
AXXCBL950HDMS
** 1 or 2 cable lengths may be specified for a PCIe add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a
shorter cable is specified. Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600WT2 and is the answer not in the manual?

Intel S2600WT2 Specifications

General IconGeneral
BrandIntel
ModelS2600WT2
CategoryServer Board
LanguageEnglish

Related product manuals