What causes incorrect fan speed in Intergas Boiler?
K
Kristopher DorseySep 7, 2025
If your Intergas Boiler has an incorrect fan speed, check the following:
* Ensure the fan isn't catching on the casing.
* Check the wiring between the fan and casing.
* Check the wiring for poor wire contact.
* Replace the fan if necessary.
D
Dana HessSep 8, 2025
How to restore power if it's reduced in Intergas Combi Compact HRE 28/24?
A
Alexandra LutzSep 8, 2025
If your Intergas Boiler's power is reduced, check the appliance and flue system for fouling and clean them.
B
baileycarlosSep 10, 2025
What should I do if my Intergas Combi Compact HRE 28/24 shows a sensor fault after a self check?
J
jonathanhansenSep 12, 2025
If your Intergas Boiler displays a sensor fault after a self-check, replace S1 and/or S2.
W
William VillarrealSep 12, 2025
What to do if the temperature is too high in Intergas Combi Compact HRE 28/24?
S
Susan WarnerSep 12, 2025
If your Intergas Boiler is overheating, possible solutions include:
* Removing air from the installation.
* Ensuring the pump is running.
* Verifying sufficient flow in the installation, checking that radiators are open, and ensuring the pump setting isn't too low.
* Checking if the flow switch is sticking.
P
Peter MurphySep 13, 2025
What causes a poor flame signal in Intergas Boiler?
S
Sarah KellySep 13, 2025
If your Intergas Boiler has a poor flame signal, check for a blocked condensate drain and check the adjustment of the gas valve.
T
Taylor SnyderSep 15, 2025
Why is there no flame signal in my Intergas Boiler?
P
Paula DiazSep 15, 2025
If your Intergas Boiler is not showing a flame signal, make sure the gas tap is open, check for correct ignition gap, ensure proper gas supply pressure, and verify the gas valve or ignition unit is powered.