Alarm Recipient Send an exception or alarm signal to the remote management
software when an event occurs.
Notify Surveillance Center
Triggers an audible warning locally (only applies to cameras
with an audio output).
Email Sends an email to a specified address when there is a motion
detection alarm.
Note: Email settings must be configured before enabling this
option. See “To set up the email parameters” on page 19 for
further information. To send the event snapshot together with
the email, select the Attached Snapshot check box.
to Snapshot Capture a snapshot when an alarm is triggered and upload the
snapshot to NAS or an FTP server.
Note: NAS settings must be configured before uploading the
snapshot to NAS. See “NAS settings” on page 45 for further
details.
FTP settings must be configured before uploading the
snapshot to FTP.
See “To define the FTP parameters” on page
19 for further details.
To upload the snapshot to FTP and NAS when motion
detection or an alarm input is triggered, Enable Event-
triggered Snapshot must also be selected in the snapshot
parameters. See “Snapshot parameters” on page 41
Triggers external alarm outputs when an event occurs. Select
the check boxes next to individual alarm outputs or select the
Trigger Alarm Output check box to select all outputs.
Note: This option is only supported by cameras that feature an
Recording Triggers the camera recording.
To set up motion detection in normal mode:
1. From the menu toolbar, click Configuration > Event > Basic Event > Motion
Detection.
2. Select the Enable Motion Detection check box. Select Enable Dynamic Analysis
for Motion to see real-time motion events.
Note: Select Local > Rules > Disable to not have detected objects indicated by
green rectangles.
3. Select Normal from the Configuration drop-down list.
4. Click Draw Area. Click and drag the mouse on the live video image to draw an area
sensitive to motion detection.
Note: Up to eight motion detection areas can be drawn on the same image.
5. Click Stop Drawing to finish drawing. Click Clear All to delete all areas marked and
restart drawing.
6. Move the Sensitivity slider to set the sensitivity of the detection. All areas will have
the same sensitivity level.
7. Click Save to save changes.
32 TruVision 81 Series IP Camera Configuration Manual