Alarm inputs and outputs (Desktop cameras only)
To define the external alarm input:
1. From the menu toolbar, click Configuration > Event > Basic Event > Alarm Input.
2. Select the Alarm Input No. and the Alarm Type. The alarm type can be NO
(Normally Open) or NC (Normally Closed). Type a name for the alarm into the
Alarm Name box.
3. Click Save to save changes.
4. Click the Arming Schedule tab to edit the arming schedule. Click and drag along
the time bars or click on a time bar to configure arming schedule times.
Note: All scheduled times are based on the 24-hour clock. Ensure that the correct
time zone and daylight saving time settings have been configured in Configuration
> System > System Settings.
5. Click
to copy the schedule to other days by selecting the corresponding check
box next to the day.
6. Click the Copy to button to copy the schedule to other alarm inputs.
7. Click Save to save changes.
8. Click the Linkage Method tab to specify the linkage method for when an event
occurs. Select one or more response methods for the system when an alarm is
triggered. See ā€œLinkage methodsā€ on page 31 for details.
9. Click Save to save changes.
To define alarm output:
1. From the menu toolbar, click Configuration > Event > Basic Event > Alarm
Output.
2. Select an alarm output channel from the Alarm Output No. drop-down list. If
required, type a name for the alarm output in the Alarm Name box.
3. The delay time can be set to 5s, 10s, 30s, 1min, 2min, 5min, or 10min. The delay
time refers to the time duration that the alarm output remains in effect after the
alarm occurs.
4. Click Save to save changes.
5. Click the Arming Schedule tab to edit the arming schedule. Click and drag along
the time bars or click on a time bar to configure arming schedule times.
Note: All scheduled times are based on the 24-hour clock. Ensure that the correct
time zone and daylight saving time settings have been configured in Configuration
> System > System Settings.
6. Click the Copy to button to copy the schedule to other alarm inputs.
7. Click Manual Alarm to generate a test alarm. After setting a manual alarm, click
Clear Alarm to remove it.
8. Click Save to save changes.