EasyLAN Wireless Interface Kit Installation Instructions 45
Chapter 5 — Setup in IPL
Changing Passwords
To change the password for a user in IPL, the “passwd”command is used.
<STX><SI>xp,user,oldpass,newpass,retyped<ETX>
is command changes the users password. If the current password
(oldpass) is correctly typed, the password will be changed to new-
pass.  e new password must be entered twice to avoid typing errors.
e new passwords total length must be less than 128 characters. Num-
bers, uppercase letters, and metacharacters are encouraged. Comma signs
(,) are not allowed. Valid user names are admin and user.
Example:
<STX><SI>xp,admin,pass,?pw,?pw<ETX>
Active
While setting up the printers network settings, it is preferable that the
changes do not take eff ect until all the changes have been made. All set-
tings are saved to non-volatile memory immediately after the command
has been given, but they are not committed to the NIC/driver until these
current” settings have been “activated.
A reboot will cause the current settings to be used.  e alternative to
rebooting the printer is the “ACTIVE” setting. Setting this to anything
other than a “0” will cause the current settings to be activated. Reading
the ACTIVE setting will indicate whether the current settings are being
used or not. 0 indicates that the current settings are not active (changes
have been made since startup or last non-zero setting of ACTIVE). 1
indicates that the settings are being used. ACTIVE cannot be set to 0
explicitly (but is implicitly set to 0 by changing another setting). Any
changes made on the web page(s) will be activated when the user submits
the form (given that the settings are correctly entered).
Unlike Fingerprint, IPL has no distinction between setup sections.
<STX><SI>ws,ACTIVE,1<ETX>
Sets ACTIVE to 1
<STX><SI>wt,ACTIVE<ETX>
Transmits ACTIVE status

Other manuals for Intermec EasyCoder PX6i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PX6i and is the answer not in the manual?

Intermec EasyCoder PX6i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
DisplayLCD
Product colorSilver
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Media thickness2.4/10 mm
Maximum label width170 mm
Maximum label length4 m
Maximum roll diameter213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Power requirements90 - 265 VAC, 45 - 65Hz
Power consumption (standby)20 W
Power consumption (printing)125 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth482 mm
Width238 mm
Height335 mm
Weight14800 g