44 EasyLAN Wireless Interface Kit Installation Instructions
Chapter 5 — Setup in IPL
Setting Up Wireless Communication
General
Once a wired serial communication is established, see Chapter 3, page
24, you can use IPL commands to set up the necessary EasyLAN Wire-
less parameters. All settings are saved in fi les on the printer fl ash memory.
If a factory default upgrade is performed, all settings described in this
section are set to their (factory) default values.
e default allowed user is “
admin”. All settings are restricted to read-
only for all users except the allowed user, who can change all settings.
Settings beginning with a period “.” character are read-protected from
non-authorized users. Some settings are not possible to read even by
the allowed user, for instance WEP keys, which return the same string
regardless of the actual key.
Display Current User
To display who the current user is in IPL, the “whoami” command is
used.
<STX><SI>.x,whoami<ETX>
Changing User
To change the current user in IPL, the “xu” command is used.
<STX><SI>xu,user,password<ETX>
xu switches to the specifi ed user after checking the password against the
password fi le.
Valid user names are admin and user.
Everyone can become user even if user’s password is set.
Example:
<STX><SI>xu,admin,pass<ETX>
changes the current user to “admin” provided that the admin’s password
is “pass.”