INTERTEK TESTING SERVICES
Test Report Number: HK08060834-1 Page 31 of 72
FCC ID: T7HCT8015
Company: RTX Consumer Products Hong Kong Ltd. Date of Test: June 24-July 7, 2008
Model: MBU 400
Mode: VoIP Online (Through LAN)
Table 4
Radiated Emissions Data
Pursuant To FCC Part 15 Section 15.323 (d) Emissions Requirements
Polarization Frequency Measured Power Margin
(MHz) Power Limit (dB)
(dBm) (dBm)
V 39.380 -65.8 -39.5 -26.3
V 50.000 -66.7 -39.5 -27.2
V 52.490 -66.1 -39.5 -26.6
V 65.680 -65.7 -39.5 -26.2
V 78.785 -68.3 -39.5 -28.8
H 118.115 -64.7 -39.5 -25.2
H 131.225 -64.5 -39.5 -25.0
H 157.444 -65.1 -39.5 -25.6
NOTES:
1. Peak detector is used for the emission measurement.
2. All measurements were made at 3 meters.
3. Negative value in the margin column shows emission below limit.