INTERTEK TESTING SERVICES
Test Report Number: HK08060834-1 Page 53 of 72
FCC ID: T7HCT8015
Company: RTX Consumer Products Hong Kong Ltd. Date of Test: June 24-July 7, 2008
Model: MBU 400
4.23 Maximum Reaction Time, FCC Rule 15.323(c)(7).2:
The monitoring system bandwidth must have a maximum reaction time less than 50 x
SQRT (1.25/emission bandwidth B in MHz) µs for signals at the applicable threshold
level but shall not be required to be less than 50 µs. If a signal is detected that is 6 dB
or more above the applicable threshold level, the maximum reaction time shall be 35 x
SQRT (1.25/emission bandwidth B in MHz) µs but shall not be required to be less than
35 µs.
Measurements are made in accordance with ANSI C63.17 sub-clause 7.5. Test setup is
shown in section 3.3 Figure 3.3.1.
Test Results:
Test Reaction of EUT Results
1
With Interference Pulse, 50µs
B Pass
2
With Interference Pulse, 35µs
B Pass
A Could be connected in at least one channel
B Could not be connected in all channels
NA – Not applicable