(130PO) MINI SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 05/31/2021
130
PO
SAVE THESE INSTRUCTIONS
English
Page 12
LED CODE CHART
IMPORTANT
When Code “90” alarm is shown, ensure the timer of the filter pump is set
one (1) hour longer than the Saltwater System.
If the filter pump does not have a built-in timer, the filter pump needs to
be turned on/off manually every day.
LED Reading Definitions
00 Stand-By Mode (Start-up)
01 Minimum Operating Hour (1 hour remaining)
02 - 11 Operating Hours (2 - 11 hours remaining)
12 Maximum Operating Hours (12 hours remaining)
90 Alarm Code (Low Pump Flow / No Flow)
91 Alarm Code (Low Salt Level)
92 Alarm Code (High Salt Level)
93 Stand-By Mode (Operating Process finished)
“BLANK”
No Power or “Power Saving Mode” waiting to start next
Saltwater System cycle.
MAINTENANCE
IMPORTANT
Unplug the power cord before cleaning your system. Also insert the black hat-like
plugs in the strainer opening to prevent water spillage. After completing all
maintenance tasks, you must plug the power cord back in and remove the plugs.
Titanium Electrode Cleaning
The titanium electrode has a self cleaning function incorporated into the electronic control’s
programming. In most cases this self cleaning action will keep the electrode working at
optimum efficiency. If the pool water is hard (high mineral content) the electrode may require
periodic manual cleaning. To maintain maximum performance, we recommend that you open
and visually inspect the titanium electrode
(7)
monthly.
The following steps provide instructions on how to clean your cell.
Inspection and cleaning:
1
. Switch off the unit, unplug the power cord from the electrical socket.
2
. To prevent water from flowing out of the pool, unscrew the strainer grids from the strainer
connectors and insert the hat-like plugs into the strainer connectors.