261
PO
(261PO) Sand Filter Pump & Saltwater System with E.C.O. ENGLISH 7.5” X 10.3” PANTONE 295U 07/23/2014
English
SAVE THESE INSTRUCTIONS
Page 31
TROUBLESHOOTING GUIDE (continued)
INSUFFICIENT
CHLORINE
WHITEFLAKESIN
THEWATER
NOLEDDISPLAY
•
Without cyanuric acid.
•
Insufficient operating hours of
the Saltwater System.
•
The salt level in the pool water
is less than 2000ppm. This is
insufficient.
•
Chlorine loss due to intense
sunlight exposure.
•
The bather load has increased.
•
Clogged or dirty electrolytic cell.
• HighUVlevelexposure.
•
Excessive calcium hardness is
present in pool water.
•
Nopowersupply.
• RCD/GFCIhasnotreseted.
•
A power fuse has blown.
•
LED failure.
•
See “Cyanuric acid table”.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
CheckthesaltlevelwiththeTestKit.
Adjust as needed. See “Salt & Pool Water
Volumes”.
•
Use a pool cover when the pool is not in use
and/or when the unit is operating.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
• Coverthepoolwithapoolcoverfor2days
with the device running and then test the
waterusing the test strips.
• Ifthepooliscleanandclear,addstabilizer
to the water and then test the water.
•
Drainabout20to25%ofthepool
water and add fresh water to decrease
the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean
the electrolytic cell if necessary.
•
Plug the cell cord firmly into the cell
housing receptacle.
•
ResettheRCD/GFCI.
•
Contact Intex Service Center.
•
Contact Intex Service Center.
PROBLEM CAUSE SOLUTION