L
ED
Pane
l
Code
Flash & Al
arm
On
(N
OT
E:
Always
turn off the power before cleaning and servicing).
no
'!.
-
0
0
m
.
1. Circulation line is blocked.
2. Incorrect inlet and outlet hose
direction.
3. Scale
on
flow sensor pins inside the
titanium electrode.
4. Titanium electrode cord
is
loose.
5. Device
is
set
and operating
in
backwash, rinse
or
waste mode.
6. Titanium electrode failure.
1. Dirt
or
scale
on
titanium electrode
plates.
2. L
ow
salt level / No
sa
lt.
3. Titanium electrode cord
is
loose.
4. Possible electrolytic cell failure.
1. High salt level.
2.
Water
Temperature > 35°C .
3. Titanium electrode failure .
1. LED display is
off
and the "S
ERV
ICE"
light is
on
- the system does
not
power
up.
2. Control station failure.
1.The
LED
display shows a
red
dot only
and
unit does not
respond
-
the
electrodes(s)
is/are short circuited.
2.Control station failure.
If
your unit has plunger valves, ensure that
they are open.
Clear the basket and cell housing from debris
and dirt. See "Maintenance" section .
Depress
the
6-way valve, release all trapped
air
in
the circulation line.
Check the direction
of
the inlet and the outlet
ho
se. Reverse the hoses
if
necessary. See
"
Set
Up Instructions".
Clean the titanium electrode. See "Titanium
&
E.C.O. Electrodes Cleaning" section.
Plug the cord into the titanium electrode and
tighten the plug collar firmly.
Ignore the alarm, finish the backwash, rinse
or
waste operation then turn the power switch
OFF
and
ON
again
to
reset the alarm.
Contact lntex Service Center.
Remove the titanium electrode
for
inspection.
Clean
it
if
necessary. See "Titanium & E.C.O.
Electrodes Cleaning" section .
Add salt. See "Salt & Pool Water Volumes".
Pl
ug
the cord into the titanium electrode and
tighten the plug collar firmly.
Contact lntex Service Center. Replace the
cell
if
needed.
Partially drain the pool and refill it with fresh
water.
See
"Salt & Pool Water Volumes".
Contact lntex Service Center.
Household voltage
is
too high or
too
low(
±
20%).
Check the voltage is within the
range
stated
on
the
device housing.
Contact lntex
Service
Center.
Remove
and clean the electrode(s).
Replace
the
electrode(s) if
needed.
Contact lntex Service Center.

Questions and Answers: