TechnicalData
11TechnicalData
11.1Technicalspecications
Thetechnicalinformationprovidedhereafterappliestoastandardcongurationorrepresentsmaximumachievablevalues.
Thesecanchangeifaccessoriesareadded.Theprecisechangestothesevaluesaredetailedinthesectionsfortherespective
accessories.
Notethatinsomecasesthemeasuredvaluesmayvaryupto±10mm.
Permissibleoperatingandstorageconditions
TemperaturerangeforoperationaccordingtoISO7176-9:
-25°+50°C
Recommendedstoragetemperature:
15°C
TemperaturerangeforstorageaccordingtoISO7176-9:-25°+65°Cwithbatteries
-40°+65°Cwithoutbatteries
Electricalsystem
Motor
1x200W
Batteries
2x12V/12Ah(C20)leakproof/AGM
2x12V/18Ah(C20)leakproof/AGM
Mainfuse
40A
Degreeofprotection
IPX4
1
ChargingdeviceFor12AhbatteriesFor18Ahbatteries
Outputcurrent2A±
5A±5%
Outputvoltage
24Vnominal(12cells)28.8Vnominal(12cells)
1576371-C