BPD series PV pumping inverter Function parameters
42
Function
code
Name
Detailed description
Default
Modify
For models of 380V:
2.2kW5.5kW: 220.0V
P15.24
Max. voltage
reference of
Max. power
tracking
P15.23P15.28
Valid in MPPT Max. tracking voltage, the Max.
tracked voltage
The default value depends on model.
For models of 220V:
0.75kW: 80.0V
1.5kW, 2.2kW and 4kW:100.0V
For models of 380V:
2.2kW5.5kW: 220.0V
Depend
on
model
P15.25
Adjustment of
initial reference
voltage
0.0200.0V
MPPT begins to change from the reference voltage
Initial reference voltage =PV voltage-P15.25
For models of 220V, the default value is 5.0V.
For models of 380V, the default value is 10.0V.
Depend
on
model
P15.26
Upper and
lower limit time
of Vmppt
0.010.0s
When P15.26 is set to 0.0, the automatic
adjustment is invalid.
If it is not 0.0, the upper and lower limit of Vmppt
will be adjusted automatically after the time set by
P15.26. The medium value is the current bus
voltage and the limit is P15.27:
Maximum / Minimum reference voltage=Current
bus voltge±P15.27 and it will update to P15.23 and
P15.24 at the same time
0.0s
P15.27
Upper and
lower limit of
Vmppt
20.0100.0V
The adjustment of the upper and lower limit
30.0V
P15.28
Maximum
P15.246553.5V
Depend

Table of Contents