0~14
0
AO/HDO
output
functions
are
indicated
in
the
following
table:
Setting
Value
Function
Range
0
Running
frequency
0~maximum
frequency
(P0.06)
1
Setting
frequency
0~
maximum
frequency
(P0.06)
2
Motor
speed
0~2*
rated
synchronous
speed
of
motor
3
Output
current
0~2*
inverter
rated
current
4
Output
voltage
0~2*
inverter
rated
voltage
5
Reserved
6
Reserved
7
AI1
voltage/current
0~10V/0~20mA
8
AI2
voltage/current
0~10V/0~20mA
9~15
Reserved
Function
Code
Name
Description
Setting
Range
Factory
Setting
P6.13
AO1
LOW
LIMIT
0.0%~100.0%
0.0~100.0
0.0%
AO1
LOW
P6.14
OUTPUT
0.00V
~10.00V
0.00~10.00
0.00V
P6.15
AO1
UP
LIMIT
0.0%~100.0%
0.0~100.0
100.0%
AO1
UP
P6.16

Table of Contents