P0 Group--Bas
i
c Funct
i
on
Function
Name
Description
Code
0:Keypad (LED–“LOCAL/REMOT”, extinguished)
1:Terminal
Setting
Range
Factory
Setting
P0.00
Run
command
(LED–“LOCAL/REMOT”, flickering)
2:Communication
(LED–“LOCAL/REMOT”,lights on)
0~2
0
The
control
commands
of
inverter
include:
start,
stop,
forward
run,
reverse
run,
jog,
fault
reset
and
so
on.
0:
Keypad
(LED—“LOCAL/REMOT”,
extinguished);
Both
RUN
and
STOP/RST
key
are
used
for
running
command
control.
If
Multifunction
key
QUICK/JOG
is
set
as
FW
D/REV
switching
function
(Details
refer
to
instruction
of
CODE
P7.03).
In
running
status,
pressing
RUN
and
STOP/RST
in
the
same
time
will
cause
the
inverter
coast
to
stop.
1:
Terminal
(LED
–“LOCAL/REMOT”,
flickering)
The
operation,
including
forward
run,
reverse
run,
forward
jog,
reverse
jog
etc.
can
be
controlled
by
multifunctional
input
terminals.