EasyManuals Logo

INVT GD100-2R2G-SS2-PV User Manual

INVT GD100-2R2G-SS2-PV
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
Goodrive100-PV Series Solar Pumping VFD Function parameters
28
Function
code
Name
Detailed illustration of parameters
Default
Modify
name plate.
In order to ensure the
controlling
performance, please
configure the motor
according to the
standard principles, if
the gap between the
motor and the standard
one is huge, the
features of the VFD will
decrease.
Note: Resetting the
rated power (P02.01)
of the motor can
initialize the motor
parameters P02.02
P02.10.
P02.06
Stator resistor of
asynchronous
motor
0.001–65.535Ω
After the motor
parameter autotuning
finishes, the set values
of P02.06P02.10 will
be updated
automatically. These
parameters are basic
parameters controlled
by vectors which
directly impact the
Depend
on model
P02.07
Rotor resistor of
asynchronous
motor
0.001–65.535Ω
Depend
on model
P02.08
Leakage
inductance of
asynchronous
motor
0.16553.5mH
Depend
on model

Other manuals for INVT GD100-2R2G-SS2-PV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT GD100-2R2G-SS2-PV and is the answer not in the manual?

INVT GD100-2R2G-SS2-PV Specifications

General IconGeneral
BrandINVT
ModelGD100-2R2G-SS2-PV
CategoryInverter
LanguageEnglish

Related product manuals