Goodrive100-PV Series Solar Pumping VFD Function parameters
51
Function
code
Name
Detailed illustration of parameters
Default
Modify
P15.25
Initial reference
voltage display
0.02000.0V
0
P15.26
Min. voltage
reference during
max. power
tracking
0.001.00
This function code is used to set the
minimum voltage reference during
maximum power tracking. Min. voltage
reference during max. power tracking =
Solar cell panel open-circuit voltage *
P15.26. Solar cell panel open-circuit
voltage = P15.25+ P15.28
Track the maximum power in the range
of Min. voltage referenceP15.27.
P15.27 must be greater than Min.
voltage reference. The less the
difference, the faster the tracking is. The
maximum voltage needs to be in the
range. P15.26 and P15.27 can be
adjusted according to site operation.
0.70
P15.27
Max. voltage
reference during
max. power
tracking
Min. voltage reference during max.
power trackingP15.31
Valid in MPPT Max. tracking voltage,
the tracked max. voltage
The default value depends on model.
Model
Max.
voltage
reference
Max.
Vmppt
-SS2
400
400
-S2
400
400
-2
400
400
-4
750
750
400.0V

Other manuals for INVT GD100-2R2G-SS2-PV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT GD100-2R2G-SS2-PV and is the answer not in the manual?

INVT GD100-2R2G-SS2-PV Specifications

General IconGeneral
BrandINVT
ModelGD100-2R2G-SS2-PV
CategoryInverter
LanguageEnglish

Related product manuals