Goodrive100-PV Series Solar Pumping VFD   Function parameters 
43 
Detailed illustration of parameters 
of  Max.  power  tracking.  The  voltage  is 
changing until the system is stable.   
Note: If terminal 43 is valid, the function 
is invalid. 
Vmpp voltage 
keypad reference 
0.0–6553.5 V DC 
If  P15.01  is  0,  the  reference  voltage  is 
given by P15.02. (During test, reference 
voltage  should  be  lower  than  PV  input 
voltage;  otherwise,  the  system  will  run 
at lower limit of frequency). 
0.0–100.0%  (100.0%  corresponds  to 
P15.02) 
If the ratio percentage of real voltage to 
reference  voltage,  which  is  abs(bus 
voltage-reference  voltage)*100.0%/ 
reference  voltage,  exceeds  the 
deviation limit of P15.03, PI  adjustment 
is  available;  otherwise,  there  is  no  PI 
adjustment and the value is defaulted to 
be 0.0%. 
abs: absolute value 
Upper frequency 
of PI output 
P15.05–100.0%  (100.0%  corresponds 
to P00.03) 
P15.04 is used to limit the Max. value of 
target  frequency,  and  100.0% 
corresponds to P00.03. 
After  PI  adjustment,  the  target 
frequency  cannot  exceed  the  upper 
limit.