LED ones
0: Invalid
1: Valid
LED tens (for factory commissioning)
0: Light overcommission; in zone 1
1: Heavy overcommission; in zone 2
0x000–0x1223
LED ones:frequency enable selection
0: Both ∧ / ∨ keys and digital potentiometer
adjustments are valid
1: Only ∧/∨ keys adjustment is valid
2: Only digital potentiometer adjustments is valid
3: Neither ∧/∨ keys nor digital potentiometer
adjustments are valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: Valid for all frequency setting manner
2: Invalid for multi-step speed when multi-step
speed has the priority
LED hundreds: action selection during stopping
0: Setting is valid
1: Valid during running, cleared after stopping
2: Valid during running, cleared after receiving the
stop command
LED thousands: ∧ / ∨ keys and digital
potentiometer integral function
0: The integral function is valid
1: The integral function is invalid
0x000–0x221
LED ones: frequency control selection
0: UP/DOWN terminals setting valid
1: UP/DOWN terminals setting valid