Goodrive350 series high-performance multi-function inverter Chapter 6
-144-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
synchronous
motor
P04.37
VF reactive
closed-loop
proportional
coefficient of
synchronous
motor
03000
50
P04.38
VF reactive
closed-loop
integral time of
synchronous
motor
03000
30
P04.39
VF reactive
closed-loop
output limit of
synchronous
motor
016000
0
P04.40
Enable/disable IF
mode of
asynchronous
motor 1
01
0
P04.41
IF current setting
of asynchronous
motor 1
0.0200.0%
120.0%
P04.42
IF proportional
coefficient of
asynchronous
motor 1
05000
650
P04.43
IF integral
coefficient of
asynchronous
motor 1
05000
350
P04.44
IF mode cut-off
frequency
threshold of
asynchronous
motor 1
0.0020.00Hz
10.00Hz

Table of Contents