Goodrive350 series high-performance multi-function inverter Chapter 6
-146-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P05.04
Function of S4
terminal
6: Coast to stop
7: Fault reset
8: Running pause
9: External fault input
10: Frequency increase (UP)
11: Frequency decrease (DOWN)
12: Clear frequency increase/decrease setting
13: Switch-over between setup A and setup B
14: Switch-over between combination setup and
setup A
15: Switch-over between combination setup and
setup B
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
21: Acceleration/deceleration time selection 1
22: Acceleration/deceleration time selection 2
23: Simple PLC stop reset
24: Simple PLC pause
25: PID control pause
26: Wobbling frequency pause
27: Wobbling frequency reset
28: Counter reset
29: Switch-over between speed control and torque
control
30: Acceleration/deceleration disabled
31: Counter trigger
32: Reserved
33: Clear frequency increase/decrease setting
temporarily
34: DC brake
35: Switch-over between motor 1 and motor 2
36: Command switches to keypad
37: Command switches to terminal
38: Command switches to communication
39: Pre-exciting command
40: Zero out power consumption quantity
0
P05.05
Function of HDIA
terminal
0
P05.06
Function of HDIB
terminal
0

Table of Contents