Goodrive350 series high-performance multi-function inverter  Chapter 5 
-106- 
Detailed parameter description 
10: EtherCat/Profinet communication 
11: Programmable extension card 
12: Reserved 
Pre-set PID reference of 
keypad 
0: AI1 
1: AI2 
2: AI3 
3: High-speed pulse HDIA 
4: MODBUS communication 
5: PROFIBUS/CANopen/DeviceNet 
communication 
6: Ethernet communication 
7: High-speed pulse HDIB 
8: EtherCat/Profinet communication 
9: Programmable extension card 
10: Reserved 
PID output characteristics 
0: PID output is positive characteristic 
1: PID output is negative characteristic 
Limit of PID control 
deviation 
Upper limit value of PID 
output 
P09.10–100.0%  (max.  frequency  or 
voltage) 
Lower limit value of PID 
output 
-100.0%–P09.09  (max.  frequency  or 
voltage) 
Feedback offline detection 
value 
Feedback offline detection 
time 
0x0000–0x1111 
Ones:   
0: Continue integral control after the 
frequency reaches upper/lower limit 
1: Stop integral control after the