Goodrive350 series high-performance multi-function inverter  Chapter 5 
-60- 
Note:  This  kind  of  V/F  curve  separation  can  be  applied  in  various  frequency-conversion  power 
sources, however, users should be cautious of parameter setup as improper setup may damage the 
machine. 
Detailed parameter description 
0:SVC 0 
1:SVC 1 
2:SVPWM 
3:VC 
Note: If 0, 1 or 3 is selected, it is required to 
carry out motor parameter autotuning first. 
Upper limit of running 
frequency 
Lower limit of running 
frequency 
0: Asynchronous motor 
1: Synchronous motor 
Rated power of asynchronous 
motor 1 
0.01Hz–P00.03 (max. output frequency)   
Rated voltage of 
asynchronous motor 1 
V/F curve setting of motor 1 
0: Straight-type V/F curve 
1: Multi-point V/F curve 
2: Torque-down V/F curve (power 1.3) 
3: Torque-down V/F curve (power 1.7) 
4: Torque-down V/F curve (power 2.0) 
5: Customized V/F (V/F separation) 
0.0%: (automatic) 0.1%–10.0% 
Motor 1 torque boost cut-off 
0.0%–50.0% (rated frequency of motor 1) 
V/F frequency point 1 of 
motor 1 
V/F voltage point 1 of motor 1 
V/F frequency point 2 of 
motor 1 
V/F voltage point 2 of motor 1