Goodrive170-PV Series Solar Pump Inverter Function parameter list
-33-
Note: After any operation among 1–4 is
complete, the parameter restores to 0.
The upload and download functions are
not applicable to group P29. The
function is valid only for an external
keypad that is an optional part and
provides the parameter copy function.
0: No function
1–5: Reserved
6: Switch command channels in
sequence. Press QUICK/JOG key to
switch the running command reference
mode in sequence.
7: Quick commissioning mode (based on
non-factory parameter settings)
Sequence of
switching
running-command
channels by
pressing
QUICK/JOG
When P07.02 =6, set the sequence of
switching running-command channels by
pressing this key.
0: Keypad→Terminal→Communication
1: Keypad←→Terminal
2: Keypad←→Communication
3: Terminal←→Communication
Stop function
validity of
STOP/RST
Used to specify the stop function validity
of STOP/RST. For fault reset,
STOP/RST is valid in any conditions.
0: Valid only for keypad control
1: Valid both for keypad and terminal
control
2: Valid both for keypad and
communication control
3: Valid for all control modes
When the inverter is configured with the
boost module, P07.11 displays the
temperature of the boost module.
Note: P07.11 is valid only in AC mode
invalid in PV mode.
-20.0–120.0℃