Goodrive350-19 series VFD Function parameter list
- 279 -
Function
code
Name
Description
Default
value
Modify
P10.05
Running time of
1
st
step
determined by P10.37.
When simple PLC operation is selected, it is
required to set P10.02P10.33 to determine the
running frequency and running time of each
section.
Note: The symbol of multi-step speed determines
the running direction of simple PLC, and the
negative value means reverse running.
P10.02
P10.04
P10.06
P10.32
P10.30
P10.28
Deceleration time
(two sections)
Acceleration time
(two sections)
P10.03 P10.05 P10.07 P10.31 P10.33
When selecting multi-step speed running, the
multi-step speed is within the range of
-fmaxfmax, and it can be set continuously. The
start/stop of multi-step stop is also determined by
P00.01.
Goodrive350-19 series VFD can set 16-step
speed, which are set by combined codes of
multi-step terminals 14 (set by S terminal,
correspond to function code P05.01P05.06) and
correspond to multi-step speed 0 to multi-step
speed 15.
0.0s(min)
P10.06
Multi-step speed 2
0.0%
P10.07
Running time of
2
nd
step
0.0s(min)
P10.08
Multi-step speed 3
0.0%
P10.09
Running time of
3
rd
step
0.0s(min)
P10.10
Multi-step speed 4
0.0%
P10.11
Running time of
4
th
step
0.0s(min)
P10.12
Multi-step speed 5
0.0%
P10.13
Running time of
5
th
step
0.0s(min)
P10.14
Multi-step speed 6
0.0%
P10.15
Running time of
6
th
step
0.0s(min)
P10.16
Multi-step speed 7
0.0%
P10.17
Running time of
7
th
step
0.0s(min)
P10.18
Multi-step speed 8
0.0%
P10.19
Running time of
8
th
step
0.0s(min)
P10.20
Multi-step speed 9
0.0%
P10.21
Running time of
9
th
step
0.0s(min)