Read and understand the user manual completely before operating the Tiger XT instrument.
Do not use abrasive or chemical detergents to clean the Tiger XT instrument.
Tiger XT must not be exposed to atmospheres known to have an adverse effect on specific materials.
Servicing must be done in a Non Hazardous environment by ION Science authorized service centres only.
Charge Tiger XT and its Lithium ion battery packs in a Non Hazardous environment only.
Never replace primary Alkaline battery cells in a potentially explosive or hazardous location.
Ensure all electrical connections are clean and undamaged before connection.
Use supplied battery packs only on the Tiger XT.
The Tiger XT must be functionally checked prior to entering a hazardous area.
The USB port can only be used in a Non Hazardous environment.
Safety rating of the Tiger XT Instrument drops when using specific probe part numbers.
Using equipment in a manner not specified by the manufacturer may impair protection.
The instrument is intrinsically safe.
ION Science accepts no liability for errors or omissions in the manual, or consequences from its use.
Defines symbols used to indicate danger warnings, cautions, and information.
Highlights specific warnings and cautions applicable to the product.
Instructions for proper disposal of packaging and waste electrical equipment.
Software that enables full configuration of the instrument.
Details the contents of a standard TIGER XTL instrument kit and accessories.
Explains the function of each key on the TIGER XTL keypad for navigation and selection.
Ensure the inlet probe supplied is fitted to your TIGER XTL.
Press the Enter / On / Off key once to turn the TIGER XTL instrument on.
Press and hold the Enter / On / Off key for 3 seconds to turn the TIGER XTL off.
Check that your TIGER XTL has sufficient charge for use; minimum two full segments.
Recommend setting alarm levels to user specifications as soon as possible.
Describes the main central viewing screen displaying readings and soft key indicators.
Details the meaning of various icons like Memory Status, USB, Battery Status, etc.
Explains the soft key areas and how options are selected using Up/Down keys.
Instructions for powering the instrument on and off, including countdowns.
Describes access to setup functions like Calibration, Options (Backlight, Sound, Alarms, Zeroing).
How to download data logged readings and instrument settings from the TIGER XTL to a PC.
Procedure for taking snapshots of instrument calibration settings for potential recovery.
Displays the current status and properties of your TIGER XTL after it has been read.
Used to configure your TIGER XTL settings such as Backlight, Sound, and Vibrate.
Displays current firmware version and provides facilities to install new versions on the instrument.
View data logged readings downloaded from your TIGER XTL in numerical and graphical form.
Records calibration settings and lists stored snapshots for potential reset.
Recommends regular checks to ensure performance within calibration limits and record keeping.
Calibration set by ION Science Ltd during manufacture or re-calibration by authorized service centres.
Procedure for instrument user to perform calibration as part of regular instrument maintenance.
Inadequate performance may not be self-evident; equipment must be regularly inspected and maintained.
Details available battery packs: rechargeable Lithium-ion and non-rechargeable AA Alkaline.
Charge Tiger XT and Lithium ion battery packs in a Non Hazardous environment only.
Instructions for removing and replacing the rechargeable battery pack from the instrument.
Details the parts of the probe assembly and their replacement if damaged.
Essential 0.5 micron PTFE Filter Disc for protecting the MiniPID 2 Sensor; consumable.
The Probe Seal should be inspected and replaced when required.
Procedure if the instrument is immersed or splashed with water.
Instructions for handling sensitive detector components like lamps and electrode stacks.
Basic faults or diagnostics presented as symbols, which can often be corrected by pressing Enter or Esc.
Document stating the product's conformity with European Union regulations.
Specifies the minimum resolution (0.1 ppm) and detectable range (0.1-5,000 ppm).
Details the instrument's response time (T90 < 2 seconds) and accuracy (±5% reading).
Lists intrinsic safety approvals including Ex II 1G Ex ia IIC T4 Ga and operating temperature limits.
Provides information on typical operating time (24 hours) and charging times.
Details the lamp type (10.6eV krypton) and data logging capacity (80,000 entries).
Specifies Direct USB 1.1 communication and 2/3-point calibration methods.
Details alarm types, sounder level, flow rate, and operating/certified temperatures.
Provides the instrument's weight (870g) and physical dimensions (370x91x60 mm).
Explains the standard warranty and how to register for an extended warranty up to 2 years.
Contact details for ION Science Ltd - UK/Head Office: Tel, Web, Email.
Contact details for ISM ION Science Messtechnik – Germany Office: Tel, Web, Email.
Contact details for ION Science India - India Office: Tel, Web, Email.
Contact details for ION Science Inc - USA Office: Tel, Web, Email.
Contact details for ION Science Italy - Italy Office: Tel, Web, Email.
Contact details for ION Science China - China Office: Tel, Web, Email.