Page #36 background imageLoading...
Page #36 background image
IONPURE
®
VNX CEDI Modules
Page 36 IP-MAN-VNX-1019-EN.pdf
Have DC volts
increased?
Reduce flow
or reduce feed
conductivity equivalent
See separate
troubleshooting
chart for DC volts
Yes
No
Go to Next Flowchart
Product flow
increased?
Yes
Troubleshooting Flow Chart - Low CEDI Product Water Quality
Page 2 of 3
Continued from previous
flowchart
Increase
DC amperage
Check IP-Pro:
is desired quality
possible?
Yes
No
No
Is reject out psi
> product out psi?
No
Adjust product out to
2-5 psi > reject out
Yes
Go to chart for
DC Volts