EasyManuals Logo

IONPURE IP-VNX-MAX-1 User Manual

Default Icon
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
IONPURE
®
VNX CEDI Modules
Page 37 IP-MAN-VNX-1019-EN.pdf
Did cleaning
restore flow?
Clean CEDI with
NaCl/NaOH and
Na
2
CO
3
/H
2
O
2
Resin oxidized
(affects flow & quality)
or fouled
(affects quality)
Has
product flow
decreased?
Troubleshooting Flow Chart - Low CEDI Product Water Quality
Page 3 of 3
Continued from
Previous Flowchart
No
Yes
Contact Ionpure Technical
Support
www.ionpure.com
Did cleaning
restore quality?
No
Removed particulates
and/or biofilm:
review process
design & operation
Yes
Also removed
organics from resin:
review process
design & operation
Yes
No
Check feed water Cl
2
Check sanitization
procedure

Table of Contents