nanoLTE S60 AP Hardware Installation Troubleshooting
NANO_INST_43315 v200_0.5 for N4G_2.0 © ip.access Limited 2017 Page 11
4 Troubleshooting
This section covers the following topics that may be useful for troubleshooting a nanoLTE
S60 AP during installation:
• 4.1 nanoLTE S60 AP Does Not Power Up
• 4.2 nanoLTE S60 AP LEDs
• 4.3 Factory Reset
For more information on AP troubleshooting, see [TRB_43005].
4.1 nanoLTE S60 AP Does Not Power Up
Check the following:
• Verify the correct power supply is in use and that mains power is available.
• Ensure that PoE or PoE+ is not being used to attempt to power the AP. The
presence of power on the Ethernet connection has no effect on the S60 AP.
4.2 nanoLTE S60 AP LEDs
The following table shows the meaning of the status indicators under normal and fault
conditions.
LED Colour Description
Power
Off The nanoLTE AP is not switched on.
Green The nanoLTE AP is powered up normally.
Red The LED should only be Red for a short time when the
nanoLTE AP is starting up. If the LED stays Red, this means
there is a fault with the AP.
If the LED turns Red after previously turning Green, this means
that there is a hardware power fault with the nanoLTE AP.