M920 & M920W pH/Dual ORP Controller Owner’s Manual
2. Mode - pushbuon adjustments
a. Auto - red LED
b. pH standby - green LED
c. ORP1 standby - yellow LED
d. ORP2 standby - yellow LED
e. Temp display & calibrate - green LED
f. OFF mode - In standby, press and hold Mode buon for 3 seconds
to turn controller o. There is sll power to the controller in
this mode, but no dosing will occur. Press and hold to turn the
controller back on.
3. Up/Down Arrows - pushbuon adjustments of following:
• Set Level
• Dose Time
• Delay Time
• Over Timer
• High Alert
• Low Alert
• pH CalFlow
4. Flow - green LED
5. Tank 1 - red LED
6. Tank 2 - red LED
7. Electrical Connecons (peripherals)
a. pH output (le receptacle) - max. 3.3 amps @ 110/230 VAC max
b. ORP1 output (center receptacle)- max. 3.3 amps @ 110/230 VAC
max
c. ORP2 output (right receptacle) - max. 3.3 amps @ 110/230 VAC
max
d. AC power - 120VAC/240 VAC (switchable), 50-60 Hz
e. AC power protecon - Fused at .500 Amps (500 mA)
f. Flow - from ow cell
g. Tank 1 - from tank level switch (oponal)
h. Tank 2 - from tank level switch (oponal)
9