M920 & M920W pH/Dual ORP Controller Owner’s Manual
The provided connecon must allow the remote monitoring module to
access the Internet without providing any usernames, passwords, etc.
via Port 80 for outbound data only.
The best test for this ability is to connect a laptop to the Ethernet
cable and open a web browser. If the browser can open directly to the
web without credenals, the connecon will funcon properly for the
remote monitoring module (laptop Wi-Fi should be turned o when
doing this test).
a. How it works:
The remote module is programmed to “wake up” at a customer
determined interval (minutes) and send all current readings,
sengs, and alerts to the IPS Controllers remote monitoring
website.
Because the data is being sent to the website rather than the
website pulling the data from the module, the port is not le
open and a stac IP Address is not needed. This should address
any concerns regarding rewall security.
When changes are made to the controller sengs remotely,
the new sengs are delivered back to the remote monitoring
module on its next scheduled connecon.
b. Setup - Go to Secon IV-B on Page 30 for installaon
instrucons.