EasyManuals Logo

IPS Controllers M920 User Manual

IPS Controllers M920
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
M920 & M920W pH/Dual ORP Controller Owners Manual
2. Flow Cell with Flow Switch
a. An injecon-molded ow cell with integrated ow
switch houses the pH and ORP sensors, and partners with
the M920 controller to monitor the pH and ORP levels in
the water.
b. The ow switch veries that water is owing during a feed cycle,
and sends the controller instrucons to deacvate the feed if
water is not owing.
c. Operaon of this controller without a funconing ow-switch
will void the NSF Cercaon. Rounely check that the ow-
switch is funconing by closing the le valve on the boom of
the ow-cell (ow light should turn o).
3. pH and ORP Sensors
a. pH Sensor – standard (Use only IPS Controllers part # SXPH to
maintain NSF Cercaon)
b. ORP Planum Sensor – standard (Use only IPS Controllers part #
SXORP to maintain NSF Cercaon)
c. ORP Gold Sensor – for use with Salt Chlorine systems (Use only
IPS Controllers part # SXORP-G to maintain NSF Cercaon)
4. Fings – tubing connectors (2) for tapping installaon of ow cell
input/output
5. In-line Filter with 2-way valves and mounng clamps (2)
6. Tubing – 25 feet of 3/8”
7. Mounng Board – ABS plasc with mounng holes and stainless
hardware (16” x 12” standard, 24” x 19” oponal for mounng two
chemical pumps)
8. Temperature Sensor – Senses the current water temperature and
displays the temperature in the display when in Temp mode.
5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IPS Controllers M920 and is the answer not in the manual?

IPS Controllers M920 Specifications

General IconGeneral
BrandIPS Controllers
ModelM920
CategoryController
LanguageEnglish

Related product manuals