III. Installation
1. General Guide
Before installing the product, read this manual and specication. It is
installed in a place that is within the temperature range specied in this
manual and that is suitable to the enclosure rating and materials. If the
products are installed improperly, it may cause malfunction.
This is general guide for installing SONDAR ultrasonic products.
Remove the obstacles in the space between the sensor and the measured target
such as ladders, limit switches, heating spirals etc.
When mounting the sensor, keep the distance to the vessel wall.
The bottom of the sensor ould be perpendicular to the surface of water.
Do not set the maximum level into the Dead Zone range.
Avoid the intense winds and excessive exposure to direct sunlight. The strong
winds change the path of ultrasound and may cause a malfunction. If you need
to install the unit in a spot exposed to direct sunlight, sun screen must be
installed.
Keep the distance from the place where are strong noise by high voltage, high
current etc.
Install the unit in the place vibration free.
Use the product in accordance with its specications.