Isokern Gas Burner Installation Instructions
Fig. 4 - Connect gas supply
7. LEAK TEST: Tu rn on the replace gas supply,
and test at all connections for leaks using the
appropriate soapy water solution. If bubbles
appear, a leak is present. Tu rn off the gas and
tighten at all connections. Repeat until no leaks
are present. If a leak persists, turn off the gas
supply and contact the local gas company or
dealer. NEVER USE A FLAME TO CHECK FOR
LEAKS.
8. Place the remote receiver box at the right front
corner of the replace. Be sure to run its wire
in between the two grate legs on the right side
of the burner system, and that the wire remains
away from the burner system and its ame during
operation. (See Fig. 5.)
9. Spread the supplied lava rock on the oor of the
rebox around the front and sides of the burner
system. The lava rock may be placed around the
rear, top, and left side of the remote receiver box.
Leave the front of the box clear for control access.
DO NOT place any lava rock on the burner system,
or behind it.
10. Proceed to the “ISO-Flames Gas Log Assembly
Instructions” section for ember and log placement.
Fig. 5 - Remote box location
Gas Log Burner Installation (cont.)

Other manuals for Isokern IBV-36

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Isokern IBV-36 and is the answer not in the manual?

Isokern IBV-36 Specifications

General IconGeneral
BrandIsokern
ModelIBV-36
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals