Function and Features 
  Copyright ©ITECH Electronics Co., Ltd.  20 
  On( Def ) 
Turn on static current function (clear 
voltage mantissa) 
External control mode and related parameter setting 
Voltage setting mode selection 
10V or 5V setting mode selection. select by 
left/right key. 
Resistance 
Resistance setting mode selection. 10K or 5K 
setting mode selection, select by left/right 
Disable or enable this function. Select by 
Master Mount:    total number of instruments 
in parallel. 
Filter 
Set the display filter frequency of the power supply 
 
Low 
Enable sense reversed protection function 
 
Disable 
Disable sense reversed protection function 
V = 5V: The protect voltage value. Difference 
between sense voltage and output voltage. 
When exceeds the value, the protection will 
be activated. 
Delay = 0.1ms( Def ): Protect delay time. 
calibration information for last time 
 
Note 
Press 
[Shift]+[P-set](  Menu)  to view the menu items,press  [Esc]  to quit menu 
operation.Besides,press 
[Esc] button can enable you quit the function operation state. 
Restored to Factory Setting( >Reset) 
This option is used to restore all settings in the system menu to factory setting 
values. Press [Enter] to restore to factory setting values. In this case, all set 
values in the system will be restored to factory setting values, i.e., the (Def) 
mark values. 
Configure Power-On State( >Power-on) 
When the power-on parameter is set as Rst, at each time of power on, the set 
parameters of the power supply will be 0V, 0A and the power rated value. The 
parameter setting values under Setup and Function menus will also be restored 
to initial values.