Function and Features
Copyright ©ITECH Electronic Co., Ltd. 20
SN-3
The last six number of SN
EXIT
Quit the information menu
EXIT MENU
Quit the main menu
NOTE
Pressing
ESC
button can enable you to quit any function setting.
Maximum voltage set (>MAX VOLT)
The range of setting voltage is from 0V to rated voltage. You can press +
I
-
set
I
-
set
(Menu) button to enter the menu, then press direction key to
select >MAX VOLT item. Press
Enter
button to confirm. After you set the
max voltage value, the output voltage value can only be set less than the max
voltage. Our default max voltage value is the rated value.
Power-on parameters set (>P-MEN)
This item can set power on state of parameters. If you select RESET item, then
all the parameters will be initialized to the factory setting. Output voltage and
current will always be 0V/0A. Or the output value will be the same with last
power off state. The default setting is RESET item.
Power On Output State (>P-OUT)
This item can set the power on output state. If you select keep item, that
indicates the power on output state is the same with last power off output state.
If you select off item, unit will automatically in off mode when you power on.
Default setting is OFF item.
Communication (>COMM)
Our unit has provided standard communication interfaces: RS232/USB. In this
option, you can select the communication interface according to your demands.
The range of GPIB (IT6900(G) series only) address is 0-30. Besides, we have
multi-baud rate to be chosen in RS232 mode 4800, 9600, 19200, 38400, 57600,
11.52K. Data bit is 8,Check digit have three choices: NONE, ODD, EVEN.
Before you begin to carry out communication, please make sure the configure
in our unit agrees with PC configure.
Key Sound Set (>BEEP ON)
This item can set the key sound state. If in on mode, then key sound will be
there when you press buttons. If in off mode, the beeper will not make a sound.
The default set is in on mode.

Other manuals for ITech IT6900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6900 Series and is the answer not in the manual?

ITech IT6900 Series Specifications

General IconGeneral
BrandITech
ModelIT6900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals