Step 6 - Enter Values for the Job Settings
Goal:
Enter Job setting values to control specific aspects of the product label application
Map:
Beginning in the Offline mode, press the Settings button. From the Settings Menu, which
can be passcode protected (default passcode from the factory is 9999), select the Job
button choice. This enters the Job Menu selections. See section
Job Settings Screens on
page 28 for information on how to make these selections.
For a typical one tamp application, the following settings provide a good start:
† = Only visible if Auto-Retract is installed
‡ = Only visible if Label Present is installed
ProductDelay
100mS
RepeatPrint
3
TampDuration
250mS
RepeatTamp
3
HomeDelay
50mS
PrintActivation
TampReturn
AutoRetract
25mS
Step 7 - Adjust the Inlet Filter / Regulator
Goal:
Apply air to the system, adjust the incoming regulator, and verify air quality
Be certain that nothing is going to interfere with the cylinder extending or retracting, and
apply air line pressure to the system by switching on the OSHA-approved shutoff switch on
the inlet filter/regulator. Adjust the regulator by
lifting up on the knob and rotate counter-
clockwise to increase the system air pressure.
View the pressure setting on the pressure sensor
digital display, located on the air manifold. Set
the pressure between 60 and 100 psi. Once the
correct pressure is set, press down on the knob
to lock it in position. Remove the knob entirely by
lifting it up past the unlock point, if there is
concern about system tampering.