Diagraph - an ITW Company PA/4600 & PA/6000 User Manual
User Interface Page 32
User Interface
4.5 Discrete I/O
Map:
Note:
This only applies to units equipped with the optional 6145-405 Discrete I/O Kit
Screen Functionality
Use this menu to map the desired output event to the output port
number. The selection choices are identical for each of the outputs 1
through 6 (Output 1 shown at left). The outputs events will result in
either a toggle of state or a momentary 20 mS pulse, dependent on
event selected. The below table outlines the events, meaning, and
duration of output event:
Output Event Description Output
None
Nooutputeventselected None
MediaOut
Labeland/orRibbonsupplyisexhausted Steady
MediaLow
Labeland/orRibbonsupplyislow Steady
Online
Unitisonline(readytoprintandapply) Steady
NoFormat
Thereisnoformatintheprintertoprint Steady
Error
Unitisoffline,duetoerror.Thisincludes:MediaOut,AirPressure
Out,PrinterErrors,RepeatPrintorTampThresholdExceeded,etc.
Steady
Warning
Unit has experienced a condition that requires attention, but it is
stillabletorunonline.
Steady or intermittent,
dependingonevent
Cycle
Complete
Theapplycycleisfinished Momentary,20mS
CycleStart
Theapplycycleisbeginning Dependent on extension
stroketime
LabelPresent
Thelabelisonthetamp Dependentonthe time label
isonthepad
LabelReject
Thesystemisrequestingthelabelonthepadtoberejected Dependent on system reject
time
RFID/Scan
Good
The system has determined the barcode scan or RFID tag encode
wassuccessful
Momentary,20mS
RFID/ScanBad
The system has determined the barcode scan or RFID tag encode
wasunsuccessful
Momentary,20mS
RFIDVerify
Thesystemhasverifiedthetagwasencodedproperly,onproduct Momentary,20mS
RFIDNo
Verify
Thesystemcouldnotverifythetagonproduct Momentary,20mS
Note: